Rev. bras. oftalmol ; 80(3): e0012, 2021. tab, graf
Article in Portuguese | LILACS | ID: biblio-1280123

ABSTRACT

RESUMO O implante de lentes intraoculares fácicas com finalidade refrativa é uma alternativa cirúrgica eletiva segura e eficiente. Essa opção deve ser considerada de forma eletiva para tratar ametropias, nos casos em que as cirurgias de correção visual refrativa a laser na córnea apresentam maior risco de complicações, seja por características da córnea ou pela magnitude da ametropia. Este artigo traz uma revisão prospectiva das lentes fácicas disponíveis no mercado brasileiro em 2020 e suas características.


ABSTRACT Implantation of phakic intraocular lenses for refractive purpose is a safe and efficient elective surgical alternative. This option should be considered to electively treat ametropia when laser corneal refractive surgery has higher risk of complications, either due to corneal characteristics or the magnitude of ametropia. This article provides a prospective review of the phakic lenses available in the Brazilian market in 2020 and their characteristics.


Subject(s)
Astigmatism/surgery , Refractive Surgical Procedures , Phakic Intraocular Lenses , Myopia/surgery
2.
Rev. bras. oftalmol ; 80(6): e0053, 2021. tab, graf
Article in Portuguese | LILACS | ID: biblio-1351855

ABSTRACT

RESUMO Objetivo: Avaliar retrospectivamente a influência da espessura do anel intracorneano na redução do astigmatismo corneano em pacientes portadores de ceratocone. Métodos: De um banco de dados com 2.033 olhos submetidos à cirurgia de implante de anel corneano, foi selecionada uma amostra de 90 olhos com características semelhantes em relação à ceratometria e ao astigmatismo. Todos os olhos deste estudo receberam dois segmentos de comprimento de arco tradicional de aproximadamente 160°, com espessuras variadas: Grupo A recebeu dois segmentos de 150µm; Grupo B recebeu dois segmentos de 200µm, e Grupo C recebeu dois segmentos de 250µm. As variáveis analisadas foram ceratometria média e astigmatismo corneano pré e pós-operatório. Resultados: Nos olhos que receberam dois segmentos de anel de 150µm de espessura (Grupo A), houve redução média de 5,0D (10%) em relação à ceratometria média e redução média de 3,26D (57,69%) em relação ao astigmatismo corneano. Na amostra em que foram utilizados dois segmentos de 200µm (Grupo B), foi observada redução da ceratometria média de 7,0D (14,28%) e do astigmatismo corneano de 3,53D (63,6%). Já na amostra que recebeu dois segmentos de anel de 250µm de espessura (Grupo C), a redução média da ceratometria foi de 10D (20,4%) e de seu astigmatismo corneano de 2,09D (38,99%). Conclusão: Nos pacientes com ceratocone submetidos à cirurgia de anel corneano, o aumento da espessura dos segmentos implantados promove maior aplanamento da córnea, mas não o aumento em sua capacidade de reduzir o astigmatismo ceratométrico. Seria interessante a análise de uma amostra maior de pacientes, aliada a cálculos vetoriais de astigmatismo, para comprovar os achados deste estudo.


ABSTRACT Objective: To retrospectively evaluate the influence of intracorneal ring thickness on reduction of corneal astigmatism in patients with keratoconus. Methods: From a database of 2,033 eyes submitted to corneal ring implant surgery, a sample of 90 eyes with similar keratometry and astigmatism characteristics was selected. All eyes in this study received two segments of traditional arc length of approximately 160°, with varying thicknesses: Group A received two segments of 150 µm; Group B received two segments of 200 µm, and Group C received two segments of 250 µm. The variables analyzed were mean keratometry and corneal astigmatism before and after surgery. Results: In the eyes that received two 150-µm ring segments (Group A), there was a mean reduction of 5.0 D (10%) in relation to mean keratometry, and a mean reduction of 3.26 D (57.69%) in relation to corneal astigmatism. In the sample in which two 200-µm segments (Group B) were used, there was a mean reduction in keratometry of 7.0 D (14.28%) and in corneal astigmatism of 3.53 D (63.6%). In the sample receiving two 250-µm ring segments (Group C), the mean reduction in keratometry was 10 D (20.4%) and in corneal astigmatism was 2.09 D (38.99%). Conclusion: In keratoconus patients undergoing corneal ring surgery, increased thickness of the implanted segments promotes greater flattening of the cornea, but does not enhance their ability to reduce corneal astigmatism. It would be interesting to analyze a larger sample of patients, combined with vector calculations of astigmatism, to confirm the findings of this study.


Subject(s)
Humans , Adolescent , Adult , Middle Aged , Astigmatism/surgery , Prosthesis Implantation , Keratoconus/surgery , Prostheses and Implants , Astigmatism/etiology , Visual Acuity , Corneal Topography , Keratoconus/complications
3.
Arq. bras. oftalmol ; 83(6): 478-484, Nov.-Dec. 2020. tab, graf
Article in English | LILACS | ID: biblio-1153081

ABSTRACT

ABSTRACT Purpose: To investigate the impact of different sizes of steep meridian clear corneal incisions for phacoemul sification on anterior corneal higher-order aberrations. Methods: Medical records of patients who underwent 2.2-mm coaxial micro-incision cataract surgery or 2.75-mm coaxial small-incision cataract surgery were retrospectively reviewed. Only patients with preexisting anterior corneal astigmatism <2.00 diopters (D) and ≥0.50 D who underwent a steep meridian clear corneal incision were included. Primary outcomes were 3rd- to 6th-order anterior corneal higher-order aberrations with an 8-mm pupil. Anterior corneal astigmatism and effective phaco time were evaluated as secondary outcomes. Preoperative and 3-month postoperative outcomes were evaluated. Results: Anterior corneal astigmatism significantly decreased after both procedures; however, there was no significant difference found in surgically induced anterior corneal astigmatism between the two procedures (p=0.146). Although the total higher-order aberrations did not significantly change after both procedures, the group comparison showed a significant difference in surgically induced total higher-order aberrations (a decrease of 0.337 ± 1.156 mm in 2.2-mm coaxial micro-incision cataract surgery and an increase of 0.106 ± 0.521 mm in 2.75-mm coaxial small-incision cataract surgery, p=0.046). Spherical aberrations significantly decreased after 2.2-mm coaxial micro-incision cataract surgery (p=0.001), whereas they did not change significantly after 2.75-mm coaxial small-incision cataract surgery (p=0.564). Coma did not significantly change after either of the procedures. Trefoil did not significantly change after 2.2-mm coaxial micro-incision cataract surgery (p=0.361), whereas it significantly increased after 2.75-mm coaxial small-incision cataract surgery (p<0.001). There was no significant difference shown in effective phaco time between the procedures. A significantly positive correlation was shown between surgically induced anterior corneal astigmatism and coma in 2.75-mm coaxial small-incision cataract surgery (r=0.387, p=0.006). There was no significant correlation found between any surgically induced higher-order aberration changes and effective phaco time. Conclusions: The results showed that 2.2-mm coaxial micro-incision cataract surgery and 2.75-mm coaxial small-incision cataract surgery did not significantly degrade the total higher-order aberrations of the anterior cornea. However, the surgically induced changes in total higher-order aberration showed a significant difference between the two procedures, with a slight reduction after 2.2-mm coaxial micro-incision cataract surgery and a slight increase after 2.75-mm coaxial small-incision cataract surgery. Phaco time and power used during surgery had no impact on corneal aberrations.


RESUMO Objetivo: Investigar o impacto de diferentes ta manhos de incisões em córnea clara com meridiano íngreme para facoemulsificação com aberrações de mais alta ordem da córnea anterior. Métodos: Foram retrospectivamente revisados os prontuários médicos de pacientes que se submeteram a cirurgias de catarata com microincisões coaxiais de 2,2 mm ou com incisões coaxiais pequenas de 2,75 mm. Foram apenas incluídos pacientes com astigmatismo preexistente da córnea anterior <2,00 dioptrias (D) e ³0,50 D, e submetidos a incisões em córnea clara com meridiano íngreme. Os desfechos primários foram aberrações da córnea anterior da 3ª à 6ª ordem com uma pupila de 8 mm. O astigmatismo da córnea anterior e o tempo efetivo de facoemulsificação foram avaliados como desfechos secundários. Os desfechos pré-operatório e pós-operatório aos 3 meses também foram avaliados. Resultados: O astigmatismo da córnea anterior diminuiu significativamente após ambos os procedimentos, mas não se encontrou nenhuma diferença significativa entre os dois procedimentos quanto ao astigmatismo da córnea anterior, induzido pela cirurgia (p=0,146). Embora as aberrações totais de mais alta ordem não se tenham alterado significativamente após ambos procedimentos, a comparação entre os grupos revelou uma diferença significativa nas aberrações totais de mais alta ordem, induzidas pela cirurgia (uma diminuição de 0,337 ± 1,156 mm na cirurgia de catarata por microincisão coaxial de 2,2 mm e um aumento de 0,106 ± 0,521 mm na cirurgia de catarata por incisão coaxial pequena de 2,75 mm; p=0,046). A aberração esférica diminuiu significativamente após cirurgia de catarata por microincisão coaxial de 2,2 mm (p=0,001), mas não se alterou significativamente após cirurgia de catarata por incisão coaxial pequena de 2,75 mm (p=0,564). A aberração de coma não mudou significativamente após qualquer dos procedimentos. O trifólio não se alterou significativamente após cirurgia de catarata por microincisão coaxial de 2,2 mm (p=0,361), mas aumentou significativamente após cirurgia de catarata por incisão coaxial pequena de 2,75 mm (p<0,001). Nenhuma diferença significativa se evidenciou quanto ao tempo efetivo de faco-emulsificação entre os dois procedimentos. Houve uma correlação positiva significativa entre o astigmatismo da córnea anterior, induzido pela cirurgia e a aberração de coma na cirurgia de catarata por incisão coaxial pequena de 2,75 mm (r=0,387, p=0,006). Não foi encontrada correlação significativa entre as alterações nas aberrações totais de mais alta ordem, induzidas pela cirurgia e o tempo efetivo de faco-emulsificação. Conclusões: Nem a cirurgia de catarata por microincisão coaxial de 2,2 mm, nem aquela por incisão coaxial pequena de 2,75 mm degradaram significativamente as aberrações totais de mais alta ordem da córnea anterior. Porém, as alterações nas aberrações totais de mais alta ordem, induzidas pela cirurgia mostraram uma diferença significativa entre os dois procedimentos, com uma ligeira redução na cirurgia de catarata por microincisão coaxial de 2,2 mm e um pequeno aumento na cirurgia de catarata por incisão coaxial pequena de 2,75 mm. O tempo de facoemulsificação e a potência utilizada durante a cirurgia não tiveram impacto nas aberrações corneanas.


Subject(s)
Humans , Astigmatism , Cataract , Cataract Extraction , Phacoemulsification , Astigmatism/surgery , Astigmatism/etiology , Retrospective Studies , Phacoemulsification/adverse effects , Cornea/surgery , Corneal Topography , Lens Implantation, Intraocular
4.
Arq. bras. oftalmol ; 81(6): 475-480, Nov.-Dec. 2018. tab, graf
Article in English | LILACS | ID: biblio-973852

ABSTRACT

ABSTRACT Purpose: We aimed to evaluate the visual quality performance of scleral contact lenses in patients with keratoconus, pellucid marginal degeneration, and post-keratoplasty astigmatism, and their impact on quality of life. Methods: We included 40 patients (58 eyes) with keratoconus, pellucid marginal degeneration, and post-keratoplasty astigmatism who were examined between October 2014 and June 2017 and fitted with scleral contact lenses in this study. Before fitting scleral contact lenses, we noted refraction, uncorrected distance visual acuity, spectacle-corrected distance visual acuity, uncorrected contrast sensitivity, and spectacle-corrected contrast sensitivity. We performed corneal topography on and applied a questionnaire that included the National Eye Institute Visual Functioning Questionnaire to all participants. We recorded corrected contrast sensitivity and corrected distance visual acuity on the third month after fitting scleral contact lenses and requested that subjects repeat the National Eye Institute Visual Functioning Questionnaire. Results: The mean age of patients was 28.12 ± 13.19 years. Mean logMAR uncorrected distance visual acuity, spectacle-corrected distance visual acuity, and corrected distance visual acuity with scleral contact lenses were 0.91 ± 0.21 (0.40-1.80), 0.57 ± 0.12 (0.10-1.80), and 0.16 ± 0.02 (0.00-1.30), respectively. We observed significantly higher corrected distance visual acuity with scleral contact lenses compared with uncorrected distance visual acuity and spectacle-corrected distance visual acuity (p<0.05). Mean uncorrected contrast sensitivity, spectacle-corrected contrast sensitivity and CCS with scleral contact lenses were 0.97 ± 0.12 (0.30-1.65), 1.16 ± 0.51 (0.30-1.80), and 1.51 ± 0.25 (0.90-1.80), respectively. Significantly higher contrast sensitivity levels were recorded with scleral contact lenses compared with those recorded with uncorrected contrast sensitivity and spectacle-corrected contrast sensitivity (p<0.05). We found the National Eye Institute Visual Functioning Questionnaire overall score for patients with scleral contact lens treatment to be significantly higher compared with that for patients with uncorrected sight (p<0.05). Conclusion: Scleral contact lenses are an effective alternative visual correction method for keratoconus, pellucid marginal degeneration, and post-keratoplasty astigmatism. A significant increase in visual acuity and contrast sensitivity can be obtained with scleral contact lenses in patients with irregular corneas.


RESUMO Objetivo: Avaliar o desempenho da qualidade visual das lentes de contato esclerais em pacientes com ceratocone, degeneração marginal transparente e astigmatismo pós-ceratoplastia e seu impacto na qualidade de vida. Métodos: Foram incluídos 40 pacientes (58 olhos) com ceratocone, degeneração marginal transparente ou astigmatismo pós-ce­ratoplastia que foram examinados entre outubro de 2014 e junho de 2017 e adaptados com lentes de contato esclerais neste estudo. Antes de ajustar as lentes de contato esclerais, registrou-se refração, acuidade visual à distância não corrigida, acuidade visual à distância corrigida por óculos, sensibilidade ao contraste não corrigida e sensibilidade ao contraste corrigida por óculos. Rea­lizamos topografia da córnea e aplicamos um questionário que incluía o Questionário de Funcionamento Visual do National Eye Institute para todos os participantes. Registramos a sensibilidade ao contraste corrigida e corrigimos a acuidade visual à distância no terceiro mês após a adaptação das lentes de contato esclerais e solicitamos aos participantes que repetissem o Questionário de Funcionamento Visual do National Eye Institute. Resultados: A idade média dos pacientes foi de 28,12 ± 13,19 anos. A acuidade visual à distância não corrigida logMAR média, a acuidade visual à distância corrigida por óculos e a distância visual corrigida com as lentes de contato esclerais foram 0,91 ± 0,21 (0,40-1,80), 0,57 ± 0,12 (0,10-1,80), 0,16 ± 0,02 (0,00-1,30), respectivamente. Observamos uma acuidade visual à distância corrigida significativamente maior com lentes de contato esclerais em comparação à acuidade visual à distância não corrigida e à acuidade visual à distância corrigida por óculos (p<0,05). Sensibilidade ao contraste médio não corrigido, sensibilidade ao contraste corrigida por óculos e CCS com lentes de contato esclerais foram 0,97 ± 0,12 (0,30-1,65), 1,16 ± 0,51 (0,30-1,80), 1,51 ± 0,25 (0,90-1,80), respectivamente. Significativamente maiores níveis de sensibilidade ao contraste foram registrados com lentes de contato esclerais em comparação com aqueles registrados com sensibilidade ao contraste não corrigida e sensibilidade ao contraste corrigida por óculos (p<0,05). Descobrimos que a pontuação geral do Questionário de Funcionamento Visual do National Eye Institute para pacientes em tratamento com lentes de contato esclerais é significativamente maior em comparação com pacientes com visão não corrigia (p<0,05). Conclusão: As lentes de contato esclerais constituem um método alternativo eficaz de correção visual alternativa para o ceratocone, degeneração marginal transparente e o astigmatismo pós-ceratoplastia. Um aumento significativo na acuidade visual e sensibilidade ao contraste pode ser obtido com lentes de contato esclerais em pacientes com córneas irregulares.


Subject(s)
Humans , Male , Female , Adolescent , Adult , Middle Aged , Young Adult , Quality of Life , Sclera , Visual Acuity/physiology , Contact Lenses , Corneal Diseases/rehabilitation , Astigmatism/surgery , Astigmatism/rehabilitation , Surveys and Questionnaires , Corneal Topography , Keratoconus/rehabilitation
5.
Rev. bras. oftalmol ; 77(4): 207-210, jul.-ago. 2018. tab, graf
Article in Portuguese | LILACS | ID: biblio-959103

ABSTRACT

RESUMO Relatamos um caso de astigmatismo residual, após cirurgia de catarata com implante de lente intra-ocular (LIO) tórica (Acrysof Toric, Alcon, Frot Worth TX). A refração residual (+1,25 -2,50 x 105º) e o posicionamento da LIO implantada neste olho, foram correlacionados com a aberrometria total obtida por ray tracing de pontos individuais integrada à da face anterior da córnea obtida por topografia de Plácido, para cálculo das aberrações internas (iTrace, Tracey, Technologies, Houston TX). O cálculo do eixo ideal da LIO, para minimizar a refração residual foi realizado de acordo com Berdahl & Hardten (astigmatismfix.com). A rotação da LIO foi realizada com sucesso 5 meses após a cirurgia inicial para o eixo indicado, reduzindo o erro residual para +0,25 -0,25 x 61º e promovendo reabilitação visual sem correção de 20/20.


ABSTRACT We report a case of residual astigmatism after cataract surgery with toric intraocular lens (IOL) implantation (Acrysof Toric, Alcon, Frot Worth TX). Residual refraction (+1,25 -2,50 x 105º) and IOL positioning were correlated with total ray-tracing wavefront aberrometry integrated with anterior corneal surface Placido-based topography to calculate internal aberrations (iTrace, Tracey Technologies, Houston TX). The ideal IOL axis to minimize residual refraction was calculated with Berdahl & Hardten (astigmatismfix.com). IOL rotation to the indicated axis was successfully performed 5 months after initial surgery, reducing residual error to +0,25 -0,25 x 61º, promoting visual reabilitation, with final uncorrected distance visual acuity 20/20.


Subject(s)
Humans , Female , Aged , Astigmatism/surgery , Astigmatism/etiology , Rotation/adverse effects , Lens Implantation, Intraocular/adverse effects , Lenses, Intraocular/adverse effects , Postoperative Complications , Refraction, Ocular/physiology , Reoperation , Astigmatism/diagnosis , Cataract , Case Reports , Visual Acuity , Phacoemulsification , Aberrometry , Slit Lamp Microscopy
6.
Rev. bras. oftalmol ; 77(3): 159-164, May-June 2018. graf
Article in English | LILACS | ID: biblio-959083

ABSTRACT

Abstract We present a case of a 12-year-old patient with advanced keratoconus in both eyes who received a two-staged treatment in the right eye (OD) to decrease keratoconus progression rate and rehabilitate patient's vision. At the initial clinical examination, visual acuity without correction in OD was count fingers; cycloplegic refraction was -22.00 - 7,50 x 100° = 20/400; corneal topography demonstrated a curvature of 64.28 x 105° / 55.38 x 15°; and tomography (WaveLight - Allegro Oculyzer) demonstrated a curvature of 68.1 x 114° / 63.3 x 163° Q = -2.67. Initially, the patient received an intrastromal ring segment (210 mm / 200 µm) slightly off center to avoid the thinnest part of the cornea. Six months later a phakic lens was implanted in the anterior chamber. At the follow-up visit 13 months after phakic lens implantation (19 months after ring implantation), visual acuity in OD was 20/20 without correction; cycloplegic refraction was -0.50 -0.75 x 180o = 20/20; and corneal topography showed keratometry of 63.22 x 44o / 61.10 x 134o. The results demonstrated that the associated procedures were successful in decreasing irregular astigmatism and markedly improving patient's uncorrected visual acuity in OD, postponing the need for corneal transplantation to a more suitable age, if required.


Resumo Apresentamos o caso de um paciente de 12 anos de idade com ceratocone avançado em ambos os olhos, que recebeu um tratamento em dois estágios no olho direito (OD) de modo a diminuir a taxa de progressão do ceratocone e reabilitar a visão do paciente. No exame clínico inicial, a acuidade visual sem correção no OD era contar dedos; refração sob cicloplegia era -22.00 - 7,50 x 100° = 20/400; a topografia demonstrou uma curvatura de 64,28 x 105° / 55,38 x 15°; e a tomografia (WaveLight - Allegro Oculyzer) demonstrou uma curvatura de 68,1 x 114° / 63,3 x 163° Q = -2,67. Inicialmente, o paciente recebeu um segmento de anel intraestromal (210 mm /200 µm) ligeiramente fora de centro de modo a evitar a porção mais fina da córnea. Seis meses mais tarde, uma lente fácica foi implantada na câmara anterior. No acompanhamento de 13 meses após a implantação da lente fácica (19 meses após a implantação do anel), OD apresentava uma acuidade visual de 20/20 sem correção; uma refração sob cicloplegia de -0,50 -0,75 x 180o = 20/20; e a topografia da córnea demonstrou ceratometria de 63,22 x 44° / 61,10 x 134°. Os resultados demonstraram que a associação de procedimentos foi bem sucedida na diminuição do astigmatismo irregular, com uma melhora significativa da acuidade visual sem correção no OD, adiando a necessidade de transplante de córnea para uma idade mais adequada, caso necessário.


Subject(s)
Humans , Male , Child , Prostheses and Implants , Corneal Stroma/surgery , Lens Implantation, Intraocular/methods , Prosthesis Implantation/methods , Phakic Intraocular Lenses , Keratoconus/surgery , Anterior Chamber/surgery , Refraction, Ocular , Astigmatism/surgery , Visual Acuity , Biometry , Corneal Topography , Tomography, Optical Coherence , Corneal Pachymetry , Keratoconus/diagnosis , Microscopy
7.
Clinics ; 72(6): 370-377, June 2017. tab
Article in English | LILACS | ID: biblio-840083

ABSTRACT

OBJECTIVES: To describe the indications for and visual outcomes of intrastromal corneal ring segment implantation. METHODS: A large retrospective case-series chart-review study was conducted using Sorocaba Ophthalmological Hospital medical records. This study included 1222 eyes (1196 patients) that were surgically treated between November 2009 and December 2012. The following preoperative data were collected: age, gender, type of medical care and funding source, surgical technique, best-corrected visual acuity, manifest sphere and cylinder refractive error, maximum and minimum central keratometry, and pachymetry measurements of the cornea at the thinnest point and at the ring channel. The postoperative best-corrected visual acuity and patient satisfaction were also determined. The cases were classified into six groups: four keratoconus groups (severe, advanced, moderate and mild), a pellucid marginal degeneration group and a post-graft irregular astigmatism group. This study was approved by the Brazilian Registry of Clinical Trials (UTN number 1111-1182-6181, TRIAL RBR-6S72RF). RESULTS: The age (mean±standard deviation) of the patients was 31.0±10.0 years. The most prevalent pathology was keratoconus (1147 eyes, 93.8%). A correlation was found between ectasia severity and medical assistance (p<0.001), and the most serious cases was treated by the Brazilian public health system. No complications were found in a total of 1155 surgeries, and after surgery, 959 patients were satisfied. Among the 164 dissatisfied patients, the majority failed to show improved best-corrected visual acuity. CONCLUSION: Patients in the public health system underwent surgical intervention for keratoconus later than those with private sources of funding. In the vast majority of operated cases, the patients reported improvements in vision.


Subject(s)
Humans , Male , Female , Adolescent , Adult , Middle Aged , Aged , Aged, 80 and over , Young Adult , Astigmatism/surgery , Corneal Edema/surgery , Corneal Stroma/surgery , Keratoconus/surgery , Prostheses and Implants , Prosthesis Implantation , Corneal Stroma/pathology , Retrospective Studies , Severity of Illness Index , Treatment Outcome , Visual Acuity
8.
Rev. bras. oftalmol ; 76(2): 101-105, Mar.-Apr. 2017. graf
Article in Portuguese | LILACS | ID: biblio-899044

ABSTRACT

Resumo O objetivo deste artigo foi reunir estudos que reportam resultados disponíveis na literatura científica, considerando a previsibilidade, segurança, eficácia, e estabilidade das lentes intraoculares fácicas de câmara posterior. E relatar as complicações documentadas para estas lentes. A revisão criteriosa dos estudos publicados na literatura ate o momento revelam resultado satisfatórios quanto à eficácia, elevada previsibilidade, estabilidade e segurança do implante de lente intraocular de câmara posterior, para correção das miopia, hipermetropia e astigmatismo.


Abstract The objective of this article was to gather studies that report results available in the scientific literature, considering the predictability, safety, efficacy, and stability of posterior chamber phakic intraocular lenses. And report the documented complications for these lenses.


Subject(s)
Humans , Refractive Errors , Lens Implantation, Intraocular/methods , Refractive Surgical Procedures/methods , Phakic Intraocular Lenses , Postoperative Complications , Refraction, Ocular/physiology , Astigmatism/surgery , Treatment Outcome , Posterior Eye Segment/surgery , Hyperopia/surgery , Myopia/surgery
9.
Arq. bras. oftalmol ; 80(1): 17-20, Jan.-Feb. 2017. tab, graf
Article in English | LILACS | ID: biblio-838768

ABSTRACT

ABSTRACT Purpose: To report the visual rehabilitation outcomes and complications of patients fitted with mini-scleral rigid gas-permeable (RGP) contact lenses (mini-SCLs) after penetrating keratoplasty. Methods: We retrospectively reviewed 27 eyes (21 patients) that were fitted with mini-SCLs between October 2013 and December 2014. We analyzed demographic data, previous corneal disorders, visual outcomes, interval from keratoplasty to contact lens fitting, topographic and specular microscope data, fitted contact lens parameters, and complications. The patients were divided into two groups according to the elapsed time since surgery: Group A, grafts with <10 years (n=14 eyes); and Group B, grafts with ≥10 years (n=13 eyes). Results: Lens use was discontinued in four eyes, and microbial keratitis developed in one eye during follow-up. No corneal graft rejection was observed. The mean interval between grafting and initial contact lens fitting was 10.6 ± 7.3 years (range: 1-29 years). The most frequent reason for keratoplasty was keratoconus (22 eyes, 81.4%). The mean contact lens-corrected visual acuity (CLCVA) was 0.09 ± 0.12 logMar (range: 0.50-0.00 logMar). The average topographic astigmatism, mean steepest keratometry (Kmax), and average cellularity on specular microscopy were 6.19 ± 3.49 diopters (D), 58.4 ± 7.8 D, and 1,231 ± 723 cells/mm2, respectively. Conclusions: Mini-SCL use allowed successful visual rehabilitation after corneal keratoplasty, particularly in patients who required corrective lenses for low visual acuity and were unable to wear RGP contact lenses. Our results indicate that mini-scleral lenses may be an option for the treatment of corneal irregularities, such as those associated with keratoplasty.


RESUMO Objetivos: Avaliar a reabilitação visual e complicações com o uso de lentes de contato rígidas gás-permeáveis mini-esclerais em pacientes submetidos ao transplante penetrante de córnea. Métodos: Estudo retrospectivo de 27 olhos (21 pacientes) adaptados com lentes de contato mini-esclerais entre outubro de 2013 e dezembro de 2014. Informações demográficas, doença corneana prévia, acuidade visual, tempo decorrido entre transplante e adaptação da lente, dados topográficos e de microscopia especular, parâmetros da lente de contato adaptada e complicações foram analisadas. Os pacientes foram divididos em dois grupos, levando em consideração o tempo decorrido do transplante de córnea: menos de 10 anos (Grupo A, n=14 olhos) e mais de 10 anos (Grupo B, n=13 olhos). Resultados: Quatro olhos desistiram do uso da lente de contato e 1 paciente apresentou quadro de ceratite infecciosa durante o período de acompanhamento. Não ocorreu episódio de rejeição de botão corneano transplantado durante o período avaliado. O tempo médio entre o transplante e a adaptação da lente de contato foi de 10,6 ± 7,3 anos (variação de 1 a 29 anos) e a causa mais frequente de ceratoplastia foi ceratocone (22 olhos, 81,4%). A acuidade visual média corrigida com lente de contato foi de 0,09 ± 0,12 logMar (variação de 0,50 a 0.00 logMar). O astigmatismo topográfico médio foi de 6,19 ± 3,49 dioptrias (D), a ceratometria média mais curva (Kmax) foi 58,4 ± 7,8 D e a celularidade média na microscopia especular foi 1.231 ± 723 células/mm2. Conclusões: Este estudo retrospectivo mostra o sucesso da adaptação de lentes de contato mini-esclerais na reabilitação visual após o transplante de córnea, especialmente em pacientes com baixa acuidade visual com óculos e intolerância ao uso de lentes de contato rígidas gás-permeáveis. Nossos resultados demonstram que as lentes de contato mini-esclerais são um opção para córneas com irregularidades corneanas, assim como aquelas após o transplante de córnea.


Subject(s)
Humans , Female , Adolescent , Adult , Middle Aged , Aged , Astigmatism/surgery , Keratoplasty, Penetrating/rehabilitation , Contact Lenses/adverse effects , Keratitis/rehabilitation , Keratoconus/surgery , Postoperative Complications , Astigmatism/complications , Time Factors , Visual Acuity , Retrospective Studies , Keratoplasty, Penetrating/adverse effects , Treatment Outcome
10.
Rev. cuba. med. mil ; 44(4): 379-388, oct.-dic. 2015. tab
Article in Spanish | LILACS, CUMED | ID: lil-777055

ABSTRACT

INTRODUCCIÓN: la queratomielusis es un procedimiento quirúrgico de valor en el tratamiento de las ametropías. OBJETIVO: determinar los resultados de la queratomileusis "in situ" asistida por láser de excímeros (LASIK) en la corrección del astigmatismo miópico. MÉTODOS: se realizó un estudio retrospectivo de 73 pacientes con astigmatismo miópico, operados con la técnica LASIK durante el año 2013 en el Hospital Militar "Dr. Carlos J. Finlay". Las variables fueron: edad, sexo, agudeza visual con corrección pre y postoperatorias, equivalente esférico, complicaciones trans-operatorias, postoperatorias inmediatas y tardías. Para el procesamiento de la información se utilizó programa SPSS. RESULTADOS: se mantuvo la agudeza visual previa corregida y no se detectaron complicaciones graves o irreversibles. Se observaron cambios significativos en las variables estudiadas con tendencia a la emetropía para un 92,3 %. CONCLUSIÓN: LASIK es una técnica segura y útil para la corrección del astigmatismo miópico, que permite mejorar la agudeza visual.


OBJETIVE: to determinate the results of Excímer laser assisted "in situ" keratomileusis (LASIK)in the correction of myopic astigmatism. METHODS: a descriptive, retrospective study of the results was performed after surgery LASIK in 73 patients with myopic astigmatism. The variables were: age, sex, pre and postoperative visual acuity without correction, spherical equivalent, intraoperative complications, postoperative immediate and late complications. Significant changes were observed in all the variables studied tending to emmetropia and 92.3 %. RESULTS: with the use of this surgical technique the corrected previous visual acuity remained and not serious or irreversible complications were detected. CONCLUSIONS: Lasik is a safe and useful technique for the correction of myopic astigmatism that improves visual acuity.


Subject(s)
Humans , Astigmatism/surgery , Electronic Data Processing/statistics & numerical data , Visual Acuity , Keratomileusis, Laser In Situ/methods , Emmetropia , Retrospective Studies
11.
Rev. bras. oftalmol ; 74(2): 102-105, Mar-Apr/2015. graf
Article in Portuguese | LILACS | ID: lil-744628

ABSTRACT

High astigmatism correction represents a challenge for the refractive surgeon with current available technology. Excimer laser correction should be considered as an option in the available therapeutic arsenal. We report a patient with astigmatism higher than eight diopters to whom it was used a treatment with LASIK (Laser Assisted In Situ Keratomileusis) in two surgical moments, using a new generation of excimer laser with an optimized aspheric profile.


O alto astigmatismo representa um desafio para o cirurgião refrativo devido à limitação da tecnologia atualmente disponível. A correção com excimer laser deve ser considerada uma opção no arsenal terapêutico disponível. Apresentamos um paciente com astigmatismo superior a 8 dioptrias que realizaou um tratamento com a técnica LASIK (Laser Assisted in Situ Keratomileusis) em dois tempos cirúrgicos, utilizando uma nova geração de excimer laser com perfil asférico otimizado.


Subject(s)
Humans , Male , Adult , Astigmatism/surgery , Keratomileusis, Laser In Situ
12.
Egyptian Journal of Hospital Medicine [The]. 2015; 60 (July): 354-362
in English | IMEMR | ID: emr-173936

ABSTRACT

Purpose: To assess the efficacy, safety and stability of LASIK surgery for treatment of low to moderate degree hyperopia and hyperopic astigmatism


Patients and methods: The study included 34 eyes in 17 patients [7 males, and 10 females] with bilateral low to moderate degree hyperopia or hyperopic astigmatism. Their mean age +/- SD was 26.7 +/- 4.1 years. Range of hyperopia was between +1.75 to +5.50 D, astigmatic errors range was 0.00 to -1.50 D while the spherical equivalent refraction ranged from +1.4 to + 4.8 D. Patients included in this study had a stable refraction for at least one year. All patients underwent bilateral LASIK surgery in the same session in Dr Soliman Faqeeh Hospital [DSFH] and the Eye Subspecialty Center [ESC]using the ALLEGRETTO EYE - Q Excimer Laser machine


Results: UCVA after one year was 20/20 or better in 30 eyes [88.2%], 20/30 or better in 32 eyes [94.1%] and 20/40 or better in 34 eyes [100%], while BCVA was 20/20 or better in 33 eyes [97.1%] and 20/40 or better in 34 eyes [100%]. There was no decrease in UCVA after LASIK surgery. One eye [2.9%] showed 2 lines drop in BCVA after LASIK surgery due to broad wrinkles of the flap. The flap was lifted after one day; trial to flatten the wrinkles showed incomplete resolution. One eye [2.9%] showed diffuse lamellar keratitis [DLK] at one week after LASIK surgery. There was regression in the manifest spherical equivalent refraction one year after LASIK surgery as compared with that at one month, but the difference was statistically insignificant [P=O.46]. The mean score of patient satisfaction was 9.4 at one year postoperatively


Conclusion: LASIK surgery is a safe, predictable, stable and effective for treatment of mild to moderate degree hyperopia and hyperopic astigmatism. No significant regression in UCVA, BCVA or manifest refraction was reported up to 12 months follow up


Subject(s)
Humans , Male , Female , Adult , Hyperopia/surgery , Astigmatism/surgery
13.
Arq. bras. oftalmol ; 77(3): 159-163, May-Jun/2014. tab, graf
Article in English | LILACS | ID: lil-723831

ABSTRACT

Purpose: To assess the reliability and reproducibility of static cyclotorsion correction (SCC) measurements made using the Schwind Amaris Excimer laser in patients undergoing LASIK or PRK, and compare the outcomes of treating astigmatism with and without SCC. Methods: Eighty eyes of 40 patients were included in this study. All eyes underwent 2 or 3 sets of five measurements: before and after speculum placement, and after flap-lift (in LASIK cases). We assessed the reproducibility, accuracy, and the percentage of "no catch" measurements. The astigmatism was calculated pre-and 3-months-postoperatively by vector analysis. Results: The mean age of the patients was 23.67 ± 4.19 years. Preoperative spherical equivalent and astigmatism were -2.56 ± 2.86 D and +1.36 ± 0.98 D, respectively. The mean measurement time was 15.1 seconds per measurement. The percentages of "no catch" were: 63.8%, 14.9%, and 26.9%; pre-speculum, post-speculum, and post flap-lift, respectively. Cyclotorsion of ≥±2º was seen in 41.25% and 66% of the cases before and after the flap-lift, respectively. Significant cyclotorsion (≥±5º) was seen in 12.50% and 18% of the eyes pre and post flap-lift. The mean astigmatism dropped from +1.53 D@1º to +0.34D@3º when SCC was used and from +1.86D@1º to +0.23D@7º when SCC was not used. No statistical difference was noticed between the groups (p>0.05) in the postoperative residual astigmatism. A postoperative astigmatism of ≥1 D was seen in 10% and 20% of eyes with and without SCC, respectively (p<0.01). Conclusion: Although not always feasible, the SCC measurement is a simple and useful tool. Postoperative astigmatism showed less variability when SCC was used. .


Objetivo: Avaliar a confiabilidade e reprodutibilidade da correção da medida de ciclotorção estática (SCC), realizada com o excimer laser Schwind Amaris em pacientes submetidos a LASIK ou PRK, e comparar os resultados do tratamento de astigmatismo com e sem SCC. Método: Oitenta olhos (40 pacientes). Todos os olhos foram submetidos a 2 ou 3 séries de 5 medições: antes e após a colocação do espéculo, e depois do levantamento do flap (nos casos de LASIK). Foram avaliadas a reprodutibilidade, a precisão e a porcentagem de medições "não obtidas". O astigmatismo foi avaliado no pré-operatório e aos 3 meses de pós-operatório, por meio de análise vetorial. Resultados: A idade foi 23,67 ± 4,19 anos. O equivalente esférico e o astigmatismo pré-operatórios foram -2,56 ± 2,86 D, e 1,36 ± 0,98 D, respectivamente. O tempo de medição médio foi 15,1 segundos por medição; as porcentagens de medidas "não obtidas" foram: 63,8%, 14,9% e 26,9%; pré, pós-espéculo, e pós-levantamento do flap, respectivamente. Ciclotorção ≥±2º foi observada em 41,25% e 66 % dos casos pré e pós-levantamento do flap. Ciclotorção significativa (≥±5º) foi observada em 12,50% e 18% pré e pós-levantamento do flap. A média do astigmatismo diminuiu de 1,53D @ 1º para 0,34D @ 3º quando SCC foi usado e de 1,86D @ 1º a 0,23D @7º quando SCC não foi usado. O astigmatismo residual pós-operatório não foi estatisticamente diferente entre os grupos (p>0,05). O astigmatismo pós-operatório ≥1D foi observado em 10% e 20 % dos olhos com e sem SCC, respectivamente (p<0,01). Conclusão: A medição do SCC é fácil e útil, apesar de nem sempre ...


Subject(s)
Adult , Female , Humans , Male , Young Adult , Astigmatism/physiopathology , Astigmatism/surgery , Keratomileusis, Laser In Situ/methods , Lasers, Excimer/therapeutic use , Torsion Abnormality/physiopathology , Torsion Abnormality/surgery , Cornea/surgery , Lasers, Excimer , Patient Positioning , Prospective Studies , Reproducibility of Results , Surgical Flaps , Time Factors , Treatment Outcome , Visual Acuity
14.
Arq. bras. oftalmol ; 77(2): 125-131, Mar-Apr/2014. tab, graf
Article in English | LILACS | ID: lil-716258

ABSTRACT

Correction of corneal astigmatism is a key element of cataract surgery, since post-surgical residual astigmatism can compromise the patient's uncorrected visual acuity. Toric intraocular lenses (IOLs) compensate for corneal astigmatism at the time of surgery, correcting ocular astigmatism. They are a predictable treatment. However, accurate measurement of corneal astigmatism is mandatory for choosing the correct toric IOL power and for planning optimal alignment. When calculating the power of toric IOLs, it is important to consider anterior and posterior corneal astigmatism, along with the surgically induced astigmatism. Accurate toric lens alignment along the calculated meridian is also crucial to achieve effective astigmatism correction. There are several techniques to guide IOL alignment, including the traditional manual marking technique and automated systems based on anatomic and topographic landmarks. The aim of this review is to provide an overview on astigmatism management with toric IOLs, including relevant patient selection criteria, corneal astigmatism measurement, toric IOL power calculation, toric IOL alignment, clinical outcomes and complications.


O tratamento do astigmatismo corneal é um fator importante na cirurgia de catarata, uma vez que o astigmatismo residual pode comprometer a acuidade visual não corrigida do paciente após a cirurgia. Lentes intraoculares (LIOs) tóricas compensam o astigmatismo corneal no momento da cirurgia, corrigindo o astigmatismo ocular. Ademais, constituem um tratamento previsível. Entretanto, é necessário obter uma medida precisa do astigmatismo corneal para selecionar o poder correto da LIO tórica e para planejar o melhor alinhamento da mesma. No cálculo do poder da LIO tórica, é importante considerar o astigmatismo das superfícies anterior e posterior da córnea, além do astigmatismo induzido na cirurgia. O alinhamento da lente tórica no meridiano planejado é essencial para se obter uma correção efetiva do astigmatismo. Há várias técnicas para guiar o alinhamento da LIO, incluindo a técnica de marcação manual tradicional e sistemas que se baseiam em pontos de referência anatômicos e topográficos. O objetivo desse artigo de revisão é discutir o uso de LIOs tóricas no tratamento de astigmatismo corneal, incluindo os critérios de seleção dos pacientes, a medida do astigmatismo corneal, o cálculo do poder da LIO tórica, o alinhamento da LIO tórica, os resultados clínicos e as complicações.


Subject(s)
Humans , Astigmatism/surgery , Lenses, Intraocular , Lens Implantation, Intraocular/methods , Treatment Outcome , Visual Acuity
15.
Arq. bras. oftalmol ; 77(2): 71-75, Mar-Apr/2014. tab, graf
Article in English | LILACS | ID: lil-716265

ABSTRACT

Purpose: To assess the postoperative outcomes of a novel toric multifocal in traocular lens (IOL) in patients with cataract and corneal astigmatism. Methods: This prospective nonrandomized study included patients with cataract, corneal astigmatism, and a motivation for spectacle independence. In all patients, a Rayner M-flex® T toric IOL was implanted in the capsular bag. Three months after surgery, the distance, intermediate, and near visual acuities; spherical equivalent; residual refractive astigmatism; defocus curve; and contrast sensitivity were evaluated. A patient satisfaction and visual phenomena questionnaire was administered to all patients. Results: Thirty-four eyes of 18 patients were included in this study. Three months after surgery, the mean corrected distance visual acuity (logMAR) was 0.00 ± 0.08 at 6 m, 0.20 ± 0.09 at 70 cm, and 0.08 ± 0.11 at 40 cm. Uncorrected distance vision acuity was 20/40 or better in 100% eyes. The preoperative mean refractive cylinder (RC) was -2.19 (SD: ± 0.53). After a 3-month follow-up, the average RC was -0.44 D (SD: ± 0.27; p<0.001). Contrast sensitivity levels were high. At the last follow-up, 87.5% patients were spectacle-independent for near, intermediate, and distance vision, and approximately 44% patients reported halos and glare. Conclusion: Toric multifocal IOL implantation in patients with cataract and corneal astigmatism using the Rayner M-flex® T toric IOL was a simple, safe, and accurate option. This technology provides surgeons with a feasible option for meeting patient expectations of an enhanced lifestyle resulting from decreased spectacle dependence. .


Objetivo: Avaliar o resultado pós-operatório de uma nova lente intraocular (LIO) multifocal tórica implantada em pacientes com catarata e astigmatismo corneano. Métodos: Estudo prospectivo não randomizado envolvendo pacientes com catarata, astigmatismo corneano, e motivação para eliminar a dependência dos óculos. Em todos os casos, a lente intraocular tórica Rayner M-flex® T foi implantada dentro do saco capsular. Três meses pós-operatório foram avaliados: acuidade visual para longe, intermediário e perto; equivalente esférico; astigmatismo refracional residual; curva de defocus e sensibilidade ao contraste. Ao final do estudo um questionário referente à satisfação visual foi aplicado. Resultados: Trinta e quatro olhos de 18 pacientes foram incluídos no estudo. Após 3 meses de pós-operatório, a acuidade visual corrigida para longe (logMAR) era de 0,00 ± 0,08 a 6 m, 0,20 ± 0,09 a 70 cm e 0,08 ± 0,11 a 40 cm. A acuidade visual sem correcão foi de 20/40, ou melhor, em 100% dos olhos. A média do cilindro refracional pré-operatório era de -2,19 (DP: ± 0,53). Após o seguimento de 3 meses a média do cilindro refracional era de -0,44 D (DP: ± 0,27) (p<0,001). Os níveis de sensibilidade ao contraste foram elevados. Ao final do seguimento, 87,5% dos pacientes estavam independentes dos óculos para perto, intermediário e para longe, e aproximadamente 44% dos pacientes relatavam halos e glare. Conclusão: O implante de uma lente intraocular multifocal em pacientes com catarata e astigmatismo corneano utilizando a lente intraocular tórica Rayner M-flex® T foi uma opção simples, segura e acurada. Essa nova tecnologia oferece ao cirurgião uma maneira passível de se atingir as expectativas dos pacientes em relação ...


Subject(s)
Aged , Female , Humans , Male , Astigmatism/surgery , Cataract Extraction/methods , Cataract/complications , Lenses, Intraocular , Lens Implantation, Intraocular/methods , Astigmatism/complications , Cataract/physiopathology , Contrast Sensitivity/physiology , Patient Satisfaction , Prospective Studies , Treatment Outcome , Visual Acuity/physiology
16.
Arq. bras. oftalmol ; 77(1): 40-46, Jan-Feb/2014. tab, graf
Article in English | LILACS | ID: lil-715552

ABSTRACT

Purpose: To compare the effectiveness of limbal relaxing incisions (LRI) with that of toric intraocular lens (IOL) implantation for the treatment of astigmatism during phacoemulsification using nonvectorial (predictability, safety, and efficacy) and vectorial analyses. Methods: This longitudinal observational case series assessed 62 eyes of 31 consecutive cataract patients with preoperative corneal astigmatism of 0.75-2.50 diopters (D) in both eyes. Patients were randomly assigned to 2 groups: a toric IOL group, which received toric IOLs in both eyes, and an LRI group, which received spherical IOLs associated with LRI placement in both eyes. All patients were evaluated at 1, 3, and 6 months after surgery, when refractive astigmatism analysis was performed using both nonvectorial and Alpins vectorial methods. Outcomes were assessed within each group and compared between groups. Results: The proportion of eyes within ±0.50 D of the intended correction at 3 and 6 months after surgery was 75% and 71.88%, respectively, in the LRI group and 40% and 66.67%, respectively, in the toric IOL group. In the remaining period, the proportion was greater in the toric IOL group. The safety index showed no difference at any time point. The efficacy index at 1 and 3 months after surgery was significantly higher in the toric IOL group (0.43 and 0.44, respectively) than in the LRI group (0.31 and 0.36, respectively). At 6 months after surgery, the status of eyes in the LRI group was as follows: 53.13% were undercorrected, 43.74% achieved the intended correction, and 3.13% were overcorrected. In the toric IOL group, 16.76% eyes were undercorrected, 76.67% achieved the intended correction, and 6.67% were overcorrected. The success rates for astigmatic surgery, astigmatism reduction at the intended axis, and astigmatism corrected were 43%, 62%, and 64%, respectively, in the LRI group and 57%, 81%, and 94%, respectively, in the toric IOL group. Conclusions: ...


Objetivo: Comparar incisões relaxantes limbares (IRL) e lentes intraoculares (LIO) tóricas tanto em termos não-vetoriais (efetividade, segurança e eficácia), quanto vetoriais no tratamento do astigmatismo por ocasião da facoemulsificação. Métodos: Estudo observacional longitudinal (série de casos) no qual foram avaliados 62 olhos de 31 pacientes consecutivos de catarata com astigmatismo corneano pré-operatório entre 0,75 e 2,50 dioptrias (D) para ambos os olhos. Os pacientes foram aleatoriamente distribuídos entre 2 grupos: "1" submetido a implante de lentes intraoculares AcrySof ToricTM em ambos os olhos e "2" com implante bilateral de lentes intraoculares tóricas AcrySof NaturalTM complementada por incisões relaxantes limbares. Todos os pacientes foram reavaliados com 1, 3 e 6 meses de pós-operatório, sendo feitas análises do astigmatismo refracional por métodos não-vetoriais, como pela análise vetorial de Alpins, interessando os resultados dentro de cada grupo e entre os grupos. Resultados: O porcentual de olhos entre ±0,50 D da correção pretendida no grupo incisões relaxantes limbares foi de 75 e 71,88%, respectivamente, em comparação aos 40 e 66,67% do grupo lentes intraoculares tóricas aos 3 e 6 meses de pós-operatório. Nos outros períodos avaliados, os porcentuais foram favoráveis ao grupo lentes intraoculares tóricas. O índice de segurança não demonstrou diferença em nenhum dos períodos. O índice de eficácia foi estatisticamente maior para o grupo lentes intraoculares tórica com 1 e 3 meses de pós-operatório (0,43 e 0,44), em comparação ao grupo incisões relaxantes limbares (0,31 e 0,36). Aos 6 meses, o porcentual de olhos, para o grupo incisões relaxantes limbares, foi: hipocorreção ...


Subject(s)
Aged , Aged, 80 and over , Female , Humans , Male , Middle Aged , Astigmatism/surgery , Lens Implantation, Intraocular/methods , Phacoemulsification/methods , Astigmatism/complications , Cataract/complications , Follow-Up Studies , Longitudinal Studies , Lens Implantation, Intraocular/adverse effects , Treatment Outcome , Visual Acuity
17.
Rev. bras. oftalmol ; 73(1): 11-15, Jan-Feb/2014. tab, graf
Article in English | LILACS | ID: lil-712759

ABSTRACT

Objective: To compare refractive and vectorial outcomes of limbal relaxing incisions (LRI) versus toric intraocular lenses (IOL) in the treatment of preexisting corneal astigmatism at the time of phacoemulsification. Methods: This longitudinal observational case series assessed 62 eyes of 31 consecutive cataract patients with preoperative corneal astigmatism between 0.75 and 2.50 diopters in both eyes. Patients were randomly assorted in two groups: one assigned to receive AcrySof Toric™ IOL in both eyes, and another one assigned to have AcrySof Natural™ IOL associated with LRI, also in both eyes. All patients were re-evaluated, postoperatively, at 1, 3 and 6 months, when refractive astigmatism analysis was performed using vectorial methods proposed by Thibos. Variability of outcomes within each group and between groups were assessed and compared. Results: Manifest refractive cylinder, in diopters (D), as means ± standard deviation, in the LRI group for 1-month, 3-month and 6-month re-evalutions were respectively -0.66 ± 0.30; -0.70 ± 0.21 and -0.74 ± 0.26 when compared to -0.58 ± 0.24; -0.63 ± 0.20, and -0.62 ± 0.17 in the toric IOL group. (p value ≥ 0.06). Vectorial analysis evidenced greater astigmatism reduction in the toric IOL group in the 6th postoperative month, when postoperative mean astigmatic power vector was 0.31 D, when compared to 0.37 D in the LRI group (p value = 0.00). Conclusions: A trend of slightly better refractive outcomes favoring toric IOL group was seen, although such a trend was not statistically significant. Vectorial analysis, however, suggests that the use of toric IOL may constitute a more advantageous approach in the treatment of pre-existing corneal astigmatism, simultaneously with phacoemulsification. .


Objetivo: Comparar os resultados refracionais e de análise vetorial, das incisões relaxantes limbares (IRL) versus lentes intraoculares (LIO) tóricas no tratamento do astigmatismo corneano pré-existente por ocasião da facoemulsificação. Métodos: Estudo observacional longitudinal (série de casos) no qual foram avaliados 62 olhos de 31 pacientes consecutivos de catarata com astigmatismo corneano pré-operatório entre 0,75 e 2,50 dioptrias para ambos os olhos. Os pacientes foram aleatoriamente distribuídos entre 2 grupos: um submetido a implante de LIO AcrySof Toric™ em ambos os olhos e outo grupo no qual seriam implantas LIO AcrySof Natural™ complementada por IRL, também em ambos os olhos. Todos os pacientes foram reavaliados com 1, 3 e 6 meses de pós-operatório, sendo feitas análises do astigmatismo refracional pelo métodos vetorial proposto por Alpins, interessando a variação de resultados dentro de cada grupo e entre os grupos. Resultados: O cilindro refracional manifesto, em dioptrias, expresso como média ± desvio padrão, para o grupo IRL, nas avaliações de 1, 3 e 6 meses, foram respectivamente -0,66 ± 0,30; -0,70 ± 0,21 e -0,74 ± 0,26 em comparação aos -0,58 ± 0,24; -0,63 ± 0,20 and -0,62 ± 0,17 do grupo LIO tórica (valor de p ≥ 0,06). A análise vetorial evidenciou maior redução no astigmatismo no grupo LIO tórica no 6º mês pós-operatório, para o qual vetor de poder astigmático médio foi de 0,31 D, comparado ao de 0,37 D do grupo IRL (valor de p = 0,00). Conclusões: Tendência a melhores resultados refracionais favorecendo o grupo LIO tórica foi encontrada, entretanto, significância estatística não foi evidenciada ao longo do estudo. A análise vetorial, sugere ...


Subject(s)
Humans , Male , Female , Aged , Astigmatism/surgery , Limbus Corneae/surgery , Phacoemulsification/methods , Cornea/surgery , Lens Implantation, Intraocular , Lenses, Intraocular , Refraction, Ocular/physiology , Astigmatism/physiopathology , Cataract , Visual Acuity/physiology , Longitudinal Studies , Cornea/physiopathology , Corneal Topography , Diagnostic Techniques, Ophthalmological , Observational Study
18.
Rev. Soc. Colomb. Oftalmol ; 47(2): 118-126, 2014. ilus. graf. tab.
Article in Spanish | LILACS, COLNAL | ID: biblio-967688

ABSTRACT

Objetivo: evaluar los resultados visuales después de cirugía de catarata con implante de lente multifocal tórico. Materiales y Métodos: se realizó un estudio observacional descriptivo tipo serie de casos, de pacientes que se operaron de catarata con implante de lente multifocal tórico Acrysoft IQ Restor (Alcon Labs, Inc, Fort Worth Texas) desde Abril del 2011 hasta Abril de 2013 en la Fundación Oftalmológica de Santander (FOSCAL). Se evaluaron la agudeza visual sin corrección en visión lejana (AVSCVL, a 6 m) y cercana (AVSCVC a 40cm), el equivalente esférico postoperatorio (EEPOP), el astigmatismo refractivo residual, el astigmatismo inducido por el cirujano (AIC) y el uso de gafas a los 3 meses del post-operatorio. Resultados: el estudio incluyó 36 ojos (23 pacientes) con catarata y astigmatismo corneal. La AVSCVL promedio post-operatoria fue 0.21 logMAR, la AVSCVC promedio post-operatoria fue 0.22 logMAR. El EEPOP fué 0.1 D. El astigmatismo refractivo residual promedio fue -0.34 D. El astigmatismo inducido por el cirujano fue de 0.36 D. El uso de gafas para la visión lejana, próxima y en ambas distancias fue de 0%, 13% y 17% respectivamente. El 65% del total de los pacientes no usa gafas. Conclusión: el implante de lente multifocal tórico en pacientes con catarata y astigmatismo corneal regular muestra muy buenos resultados en la agudeza visual lejana y cercana, permitiendo a los pacientes gozar de independencia de gafas.


Objective: to evaluate visual outcomes after cataract surgery with toric multifocal intraocular lens (IOL). Materials and Methods: this is a case series study which included patients who had cataract surgery with implantation of an Acrysof IQ Restor toric IOL from April 2011 until April 2013 at Fundación Oftalmológica de Santander (FOSCAL). We evaluated uncorrected distance visual acuity, uncorrected near visual acuity, spherical equivalent refraction, residual astigmatism, surgeon induced astigmatism and spectacles use at 3 months post-operatively. Results: the study included 36 eyes (23 patients) with cataract and corneal astigmatism. The mean UCDVA was 0.21 logMAR, mean UCNVA was 0.22 logMAR. The spherical equivalent was 0.1 D. The residual refractive astigmatism was -0.34 D. Surgeon-induced astigmatism was 0.36 D. The use of glasses for distance vision, near vision and both was 0 %, 13 % and 17 %, respectively. 65% of the patients don't wear glasses. Conclusion: implantation of toric multifocal IOL in patients with cataract and regular corneal astigmatism showed good outcomes in distance and near vision, allowing patients get independence from spectacle wear.


Subject(s)
Cataract Extraction/trends , Astigmatism/surgery , Ophthalmologic Surgical Procedures/trends , Lens Implantation, Intraocular/trends
19.
Arq. bras. oftalmol ; 76(6): 339-340, nov.-dez. 2013. graf, tab
Article in English | LILACS | ID: lil-701282

ABSTRACT

PURPOSE: The aim of this study was to verify the presence of cyclotorsion in eyes that underwent laser refractive surgery. METHODS: This was a comparative observational study, which analyzed the medical records of 61 patients (104 eyes) who underwent laser refractive surgery and compared the axis of astigmatism of the sitting and the supine positions. Regarding the gender, 37.5% were male and 62.5% were female. The age ranged from 20 to 54 years old, with the median of 29 years. The lowest degree of astigmatism was -0.75 cylinder diopters (DC) and the highest was -6.50 DC, with a mean of -3.06 ± 1.16 DC. First, the axis of astigmatism of the seated patient was captured by the Schwind's ORK-CAM. In a second moment, inside the operating room, the axis of astigmatism of the patient in supine position was captured by the laser equipment's own camera (Schwind Amaris®), which was then compared with the previous measure. The incyclotorsion was defined by a minus sign (-) and the excyclotorsion, by a plus sign (+). RESULTS: The maximum excyclotorsion was +7.7 and the maximum incyclotorsion was -11.0 degrees. The mean torsion (excyclo or incyclo) was 2.74 (56.7%), with a standard deviation of 2.30 degrees. There was no statistically significant change (p=0.985) in the axis of astigmatism between patients sitting versus supine. CONCLUSION: There was clinically significant cyclotorsion in 36.5% of the eyes submitted to laser correction.


OBJETIVO: Verificar a presença de ciclotorção em olhos submetidos à cirurgia refrativa a laser. MÉTODOS: Realizou-se um estudo observacional comparativo, feito pela avaliação dos prontuários de 61 indivíduos (104 olhos) submetidos à cirurgia refrativa a laser, para comparar a orientação do astigmatismo ocular na posição sentada e em decúbito dorsal. Foram computados 37,5% de homens com idade variando de 20 a 54 anos, com mediana de 29 anos. O menor grau de astigmatismo avaliado foi de -0,75 e o maior de -6,50, com média de -3,06 ± 1,16 dioptrias cilíndricas (DC). A captação da orientação (eixo) do astigmatismo foi feita no primeiro momento (sentado) pelo aparelho ORK-CAM da empresa Schwind. Em um segundo momento (decúbito dorsal), na sala de cirurgia, o eixo foi captado pela câmera do próprio laser (Schwind Amaris®) para então comparar o eixo nos dois momentos. A inciclotorção foi identificada por um sinal negativo (-) e a exciclotorção por um sinal positivo (+). RESULTADOS: A exciclotorção máxima foi de +7,7 e a inciclotorção máxima de -11,0 graus. A média de torção (exciclo ou inciclo) foi de 2,74 (56,7%), com desvio padrão de 2,30 graus. Não houve variação estatisticamente significativa (p=0,985) no eixo do astigmatismo entre os indivíduos sentados versus decúbito dorsal. CONCLUSÃO: Houve ciclotorção clinicamente significativa em 36,5% dos olhos submetidos à cirurgia refrativa a laser.


Subject(s)
Adult , Female , Humans , Male , Middle Aged , Young Adult , Astigmatism/surgery , Cornea/surgery , Corneal Surgery, Laser/methods , Astigmatism/physiopathology , Cornea/physiopathology , Eye Movements , Medical Records , Reference Values , Severity of Illness Index , Statistics, Nonparametric , Supine Position , Torsion Abnormality , Treatment Outcome
20.
Arq. bras. oftalmol ; 76(5): 270-273, set.-out. 2013. ilus
Article in English | LILACS | ID: lil-690602

ABSTRACT

PURPOSE: The present study aimed to compare the postoperative contrast sensitivity functions between wavefront-guided LASIK eyes and their contralateral wavefront-guided PRK eyes. METHODS: The participants were 11 healthy subjects (mean age=32.4 ± 6.2 years) who had myopic astigmatism. The spatial contrast sensitivity functions were measured before and three times after the surgery. Psycho and a Cambridge graphic board (VSG 2/4) were used to measure luminance, red-green, and blue-yellow spatial contrast sensitivity functions (from 0.85 to 13.1 cycles/degree). Longitudinal analysis and comparison between surgeries were performed. RESULTS: There was no significant contrast sensitivity change during the one-year follow-up measurements neither for LASIK nor for PRK eyes. The comparison between procedures showed no differences at 12 months postoperative. CONCLUSIONS: The present data showed similar contrast sensitivities during one-year follow-up of wave-front guided refractive surgeries. Moreover, one year postoperative data showed no differences in the effects of either wavefront-guided LASIK or wavefront-guided PRK on the luminance and chromatic spatial contrast sensitivity functions.


OBJETIVO: A proposta do presente estudo é comparar funções de sensibilidade ao contraste obtidas após wavefront-LASIK e wavefront-PRK no olho contralateral. MÉTODOS: Os participantes foram 11 sujeitos saudáveis (idade média=32,4 ± 6,2 anos) com astigmatismo miópico. As funções de sensibilidade ao contraste espacial foram obtidas antes e três vezes após a cirurgia. O programa Psycho e uma placa gráfica da Cambridge Research Systems (VSG 2/4) permitiram gerar os estímulos com contraste espacial de luminância e cromático (verde-vermelho e azul-amarelo) de 0,85 até 13,1 ciclos/grau. Análises longitudinais e comparações entre as cirurgias foram realizadas. RESULTADOS: Não houve mudança significativa da sensibilidade ao contraste durante o primeiro ano após a cirurgia para o olho que recebeu o LASIK ou para o olho que recebeu o PRK. A comparação entre as cirurgias também foi semelhante no pós-operatório de um ano. CONCLUSÕES: Os resultados apresentados mostraram sensibilidade ao contraste semelhante durante o primeiro ano após a cirurgia refrativa com o wavefront. Além disso, no pós-operatório de um ano não houve diferença nas funções de sensibilidade ao contraste de luminância e cromático entre os olhos que receberam LASIK e os que receberam PRK.


Subject(s)
Adult , Female , Humans , Male , Astigmatism/surgery , Contrast Sensitivity/physiology , Keratomileusis, Laser In Situ/methods , Myopia/surgery , Photorefractive Keratectomy/methods , Light , Prospective Studies , Refractive Surgical Procedures/methods , Treatment Outcome
SELECTION OF CITATIONS